What's new in Version 3.2.0.0 - Fixes an issue with small time shifts (a few hundred ps) on the histogram time axis, occurring from one hardware initialization to the next - Fixes an an inversion of the selected input edge (TimeHarp 260 NANO only) - Fixes a display overflow of the elapsed time shown in TTTR mode - Fixes an issue where the sync divider was set incorrectly upon return from TTTR mode, this resulting in wrong warnings - Fixes an issue where on dual monitor systems the enlarged rate meters would appear off screen and hence invisible - The menu entry and button for access to the old (discontinued) PicoQuant user forum have been removed - Provides updated file access demos - Fixes some minor documentation errors - The file format remains unchanged What's new in Version 3.1.0.3 - Fixes an issue with sporadic timeout errors upon hardware initialization - Fixes an issue where errors occurred when Windows was set to 1 or 2 ms timer resolution - Provides a new driver to support Windows 10 with "secure boot" enabled - The file format remains unchanged What's new in Version 3.1.0.2 - Fixes an issue with stopping measurements on some PCs - Fixes an issue with unresponsive user interface on some PCs in histogramming mode - Improves histogramming throughput while reducing CPU load - The file format remains unchanged What's new in Version 3.1.0.1 - Supports new hardware versions manufactured after February 2017 - Improves histogramming throughput - Fixes an issue with DMA buffer alignment occuring with some recent PCs - Fixes an issue where debug information was not properly retrieved - Fixes an issue where opening multiple devices in multiple software instances worked only in one specific order of devices - Provides some documentation improvements - The file format remains unchanged What's new in Version 3.0.0.1 - Fixes a bug that could lead to the loss of status information - Fixes an issue where clipboard data was truncated at long time spans - Provides some documentation improvements - The file format remains unchanged What's new in Version 3.0 - Supports the latest hardware improvement of the TimeHarp 260 N - now running at 250 ps resolution (owners of older models with 1 ns resolution can request a quote for a hardware upgrade to 250 ps) - Officially supports Windows 10 - Fixes some minor bugs - The file format remains unchanged What's New in Version 2.0 - Some minor bugfixes - A new file format. The idea is to place individual header data items not in a strict file position and order but to tag the items by name, so that future additions do not harm existing software. - A new device driver in order to meet new driver signing requirements imposed by Microsoft. The new driver can now be conveniently installed by setup exe. Note that Windows versions prior to 7 are no longer supported. If you must use an older Windows version you can still use the driver of the TimeHarp 260 release version 1.1. - Supports a new hardware feature to change the dead time of the input channels for suppression of some detector artefacts. Note that this works only for TimeHarp 260 P purchased after April 2015. Old boards can be updated but must be returned to PicoQuant for a hardware modification.