    Recommended steps for a painless usage of the
     SymPhoTime 64 RemoteInterface-DLL functions
    =============================================

This document refers to V1.0.9 of the RemoteInterface-DLL and requires a
SymPhoTime 64 version >= 2.2.

Please understand all codelines herein as pseudo-code, and never intended to
instantely run under whatsoever conditions. Instead, they are to picture out
the in-general usage of the RemoteInterface DLL as supplied with SymPhoTime 64.
We hope this document may reduce the time of familiarization with the DLL.


Create an DLL import function analogous to "InitRemoteInterface_DLL ()"
from the stress client example. All DLL functions return a long int, coding
their result as either finished without error or the error number which
might be decoded to a human readable string cErrText, using the function
"RI_GetErrorText":

    long int lRet;
    char     cErrText [SPT_RI_ERRORTEXT_MAXLEN+1];

    if (PQ_ERRCODE_NO_ERROR != (lRet = InitRemoteInterface_DLL ()))
    {
      RI_GetErrorText (lRet, cErrText);
    }


Check for version compatibility:


    char cLibVersion [SPT_RI_VERSIONSTRING_MAXLEN+1];

    RI_GetLibVersion (cLibVersion);


At least if still in debugging process, provide a means to show the
debugging window. You may then compare between the received data and the
information sent by SPT as shown in the server window. While running with
enabled log, all insertations to the log are recorded with timestamp.


    if (PQ_ERRCODE_NO_ERROR == (lRet = RI_AssignLogFile ("MyLog.txt")))
    {
      RI_EnableLog (true);
      RI_AddLineToLog ("Begin of Session");
      RI_ShowLogWin ();
    }


Create a call-back function (or even more, specialized ones) 
with the respective footprints

    typedef long (__stdcall *TReceiveNumParamFunc)(char* pcIdent,
                                                   float fValue,
                                                   long  iRecNr);
and

    typedef long (__stdcall *TReceiveStrParamFunc)(char* pcIdent,
                                                   char* pcValue,
                                                   long  iRecNr);

If passed over to the DLL with the start of a new measurement (in the case 
of the TReceiveNumParamFunc typed call-back function) or if explicitely 
registered (in case of the TReceiveStrParamFunc typed call-back function) 
they will be called on each incoming feedback frame, once for each named 
value in each frame. These frames will be sent by SPT64 and SPT32 as well 
in intervals of approx. 1.2 seconds.
For the names of the values transmitted, refer to the document
  "Feedback_Values.txt"

Let this call-back functions have side effects, e.g.

  - in copying the values received to certain memory locations depending
    on the identifier recognized, for the usage outside e.g. for displaying.
    CAVEAT: Since the function is called from the context of a DLL internal
    thread, take care of thread-saveness (use e.g. Interlocked Exchange).

  - in making the decision when to stop the measurement either directly
    inside the function or on a decision value handed over into the func-
    tion by means of a global variable.

  - in letting the function finally return the result of this decision to
    the DLL using values as given by enumeration type E_SPT_RI_STOP_REASONS
    or else

  - in letting the function always return SPT_RI_STOP_REASON_CONTINUE_OK.
    (In the later case, you have to terminate measurements explicitely by
    calling the function "RI_RequestStopMeas".)


The following example will only react on each "maxcpp" and terminate the
measurement if the value of any "maxcpp" value increases 250 counts. Consider,
that this would never stop a time trace measurement, since there will never
be a feedback sent like "maxcpp"!

    long __stdcall AnImageNumParamCallBackFunc (char* pcIdent, float fValue, long iRecNr)
    {
      long int lStopReason;
      //
      lStopReason = SPT_RI_STOP_REASON_CONTINUE_OK;
      //
      if (0 == strcmp (PQ_OPT_DATANAME_MAX_COUNTS_PER_PIXEL, pcIdent))
      {
        if (fValue > 250.0f)
        {
          lStopReason = SPT_RI_STOP_REASON_FINISHED_OK;
        }
      }
      return lStopReason;
    }


    char cFileName[256];
    char cGroupName[64];
    char cLaserName[8][256];
    
    long __stdcall AStrParamCallBackFunc (char* pcIdent, char* pcValue, long iRecNr)
    {
      long int lStopReason;
      //
      lStopReason = SPT_RI_STOP_REASON_CONTINUE_OK;
      //
      if (0 == strcmp (PQ_OPT_DATANAME_RESULTINGFILENAME, pcIdent))
      {
        strcpy (cFileName, pcValue);
      }
      //
      if (0 == strcmp (PQ_OPT_DATANAME_RESULTINGGROUPNAME, pcIdent))
      {
        strcpy (cGroupName, pcValue);
      }
      //
      if (0 == strncmp (PQ_OPT_DATANAME_LASERNAME, pcIdent, strlen(PQ_OPT_DATANAME_LASERNAME)))
      { 
        int iLaserIdx =  (pcIdent [strlen(PQ_OPT_DATANAME_LASERNAME)] - '1');      
        strcpy (cLaserName[iLaserIdx], pcValue);
      }
      //
      return lStopReason;
    }


Then create the infrastructure to hand over individual optional parameters
for the next measurement to be started. This could e.g. be:

  - the desired file name for the raw data file 
      + "Filename"
    (may contain symbolic constants, refer to the document 
    "Supported_NameTemplates.txt"; for the resulting file name check the 
    returning online-parameter "ResultingFilename"),

  - a group name 
      + "Groupname"
    i.e. the name of a subdirectory to create, if not already existing, 
    within the current working directory in the SPT64 workspace, where to 
    insert the raw data file, the measurement process is about to create.
    (may also contain symbolic constants, refer to the document 
    "Supported_NameTemplates.txt"; for the resulting group name check the 
    returning online-parameter "ResultingGroupname")

  - Controlling parameters for the PDL 828 "Sepia II" if connected
    as there are e.g.
    
      + "LaserRepetitionRate"   (as integer in Hz)
      + "LaserOn"               (as integer coded boolean array, 
                                 0 = off, else = on)
      + "LaserIntensity"        (as float array in %; SPT64 rounds to integer)
      
    (For the resulting laser repetition rate check the returning online-
    parameter "ResultingLaserRepetitionRate".)
    Notice, that the usage of these parameters implies the existence and 
    operability of a PDL 828, otherwise an error message will be launched.

  - some measurement describing information, with predefined value names,
    as there are e.g.

      + "Objective"              // string
      + "Pinhole"                // string
      + "MajorDichroic"          // string
      + "TimePerPixel"           // float, set in seconds
      + "TimePerImageEstimated"  // float, set in seconds

    Future releases may or may not provide retrieval capabilities for these.

  - comments for documentation purposes, that will be inserted into the
    resulting raw data files, too. Other than the prementioned, comments
    are not scanned nor interpreted neither now nor is this planned for
    future releases. But they may contain a huge amount of measurement
    related information, given in human readable format. They may even
    contain formatting tabs or line feeds (DOS-style recommended: <CR><LF>)


Now, for the opening handshake, call the init function "RI_Initialize"
where the parameter cHost should contain the IP address, like e.g.
"127.0.0.1", the long int parameter lPort contains the port to be used for
the comunication, (should equal 6000). If the return code equals
PQ_ERRCODE_NO_ERROR, you may rely on the SPT version string returned in
cSPTVersion.


    char     cHost[SPT_RI_HOSTNAME_MAXLEN];
    long int lPort;
    char     cSPTVersion[SPT_RI_VERSIONSTRING_MAXLEN];

    strcpy (cHost, "127.0.0.1");
    lPort = 6000;
    lRet = RI_Initialize (cHost, lPort, cSPTVersion);


If terminated without error, continue, else react on the error and maybe
retry. An error frequently made is to forget to open a workspace, resulting
in the errocode PQ_ERRCODE_NO_WORKSPACE.

Now, as the connection is approved to be free of errors, you may sent the
upper mentioned optional parameters to the DLL, e.g.:


    RI_SetOptionalString (PQ_OPT_INFONAME_GROUPNAME, "MySubdir");
    RI_SetOptionalString (PQ_OPT_INFONAME_FILENAME,  "MyRawData");

Consider, if there is already a file with the given name in the subdirectory,
the measurement will terminate with an error PQ_ERRCODE_FILE_EXISTS.

For the upper mentioned online string-parameters, register an additional handler:

   RI_RegisterStringHandler (MyStrPCBFunc);

Now, if the SPT signals to be in IDLE state, we are ready to start a measure-
ment, in this example let's record for an image.


    long int             lState;
    longbool             bRecord;
    long int             lPixX;
    long int             lPixy;
    float                fResol;
    longbool             bBiDirectionalScan;
    TReceiveNumParamFunc MyNumPCBFunc;
    TReceiveStrParamFunc MyStrPCBFunc;

    lState        = SPT_RI_STATUS_UNKNOWN;
    bRecord       = true;                     // i.e. measureement mode; false would be test mode
    lPixX         = 128;
    lPixY         = 128;
    fResol        = 1.0e-6f;                  // given in meter
    bBiDirScan    = false;                    // mono-directional scan
    MyNumPCBFunc  = AnImageParamCallBackFunc; // see above
    MyStrPCBFunc  = AStrParamCallBackFunc;    // see above
    
    do
    {
      if (PQ_ERRCODE_NO_ERROR == (lRet = RI_GetStatusText (lState = RI_GetStatus (), cStatus)))
      {
        if (lState == SPT_RI_STATUS_IDLE)
        {
          lRet = RI_RegisterStringHandler (MyStrPCBFunc);
          //
          lRet = RI_RequestImage (bRecord, lPixX, lPixY, fResol, bBiDirScan, MyNumPCBFunc);
          lState = RI_GetStatus ();
        }
        else
        {
          // show cStatus in GUI
          //
          Sleep 1000;
          //
          // IMPORTANT: Give SPT some time for the aprs measurement work;
          //            Don't poll too fast, because this would hinder SPT
          //            ever to get ready for the next measurement, again!
        }
      }
    } while ( (lRet == PQ_ERRCODE_NO_ERROR) && (lState != SPT_RI_STATUS_MEAS_RUNNING) )


If
  a) the return value is PQ_ERRCODE_NO_ERROR and
  b) the state is SPT_RI_STATUS_MEAS_RUNNING,
the measurement is accepted and running, else decode the return value and
state code and act appropriately. The illustrated state machine shall only
show the in principle possibility of reaction on changes of the state.
You should properly design your own machine according to the demands of your
respective application.

Assuming, the measurement is running, the function AnImageParamCallBackFunc
will be called for feedback transmission. If a pixel reaches more than
250 counts, the measurement will be terminated according to plan. But it
also might happen, that a user wants to stop the running measurement, for
he or she realizes a mistake in the supplied information or perhaps the
preview provided by the SPT64. On behalf of this you should provide e.g.
a button, which on click launches a stop measurement request:


    if (PQ_ERRCODE_NO_ERROR == (lRet = RI_RequestStopMeas ()))
    {
      RI_AddLineToLog ("Measurement stopped by user!");
    }


As shown in the state machine diagram, you may - in absence of error conditions - 
cycle these steps ad infinitum. Any error detected by the DLL, however, 
will change its state to "Unknown", giving you the opportunity for recovering 
measures. With stable working conditions accomplished again, you may then 
restart with the initializing sequence.


At last, if running under debugging conditions, release the logfile:


    RI_AddLineToLog ("End of Session");
    RI_EnableLog (false);
    RI_HideLogWin ();


We hope, this little doc made things easier for you.
Enjoy remote controlling your SymPhoTime!

apo (PQ).