Compact Fluorescence Lifetime Spectrometer FluoTime 100 
Features Plug and measure, compact design
  Based on Time-Correlated Single Photon Counting (TCSPC)
  Easy-to-use picosecond laser or sub-nanosecond LED excitation
  Filters for high optical throughput and highest sensitivity
  Advanced data analysis
  Ideal for research and teaching purpose
Applications Time-resolved fluorescence spectroscopy and anisotropy
  Ultra sensitive analysis
  Photochemistry
  Marker and assay development
A Brief Description

The FluoTime 100 combines the award winning miniaturized light sources from PicoQuant with a maximum troughput optical system and the versatile detection electronics. The easy of use, economically priced and space saving spectrometer contains the complete optics and electronics for recording fluorescence decays by means of Time-Correlated Single Photon Counting (TCSPC). With the FluoTime 100 decay times of down to 40 picoseconds can be resolved. The system allows operation at laser repetition rates of more than 85 MHz.

The FluoTime 100 system is designed to operate with either picosecond laser excitation and/or sub-nanosecond pulsed LEDs. High N.A. focussing and collecting optics are used to achieve ultimate sensitivity. For spectral filtering of the emission light cut-off filters are used for high light throughput. As standard detector a fast and reliable PMT will allow detection with an Instrument Response Function (IRF) of about 200 ps. The data acqusition is based on the method of Time-Correlated Single Photon Counting (TCSPC), which ensures a high temporal resolution at high sensitivities. Lifetimes tanging from picoseconds to milliseconds can be resolved using the PicoHarp 300 TCSPC module. For investigations of long lifetimes samples, the NanoHarp 250 photon counter/multiscaler is available as an option. All data acquisition functions of the FluoTime 100 spectrometer are controlled by an easy-to-use software for Windows. The software provides functions such as set-up of parameters, loading files, control of the measurement in the selected operation mode. Data analysis is done using FluoFit, which allows reconvolution of decays, saving of results and parameters, etc.

Options All laser heads and pulsed LEDs from PicoQuant
  Polarizer
  Water-cooled sample holder
  Front face sample holder
  Fiber probe
  Peltier-cooled detector
Specifications:
Download the datasheet
Measurement Examples: Lifetime measurements of common dyes
Time-Resolved Spectroscopy of Proteins using the FluoTime 100
Sensitivity of FluoTime Series Lifetime Spectrometers
Time-resolved Fluorescence Anisotropy Measurements Made Simple
Bibliography List of all publications contained in our bibliography that are related to the FluoTime 100
  Please see our bibliography for many other application examples